SciAps
Portable Benchtop

SciAps Portable Benchtop XRF PowerHouse X

The first field-portable XRF with an 80 kV X-ray tube — measure heavy REEs like Tb, Dy, Ho, Er and Yb.

Conventional portable XRF stops at 50 kV, leaving heavy rare earths under-excited and buried in spectral overlaps. The PowerHouse is a closed-beam benchtop you can carry: three beams at 10, 40 and 80 kV, reaching 5–25 ppm across the REE suite in minutes rather than weeks waiting on a lab.

Applications

One Benchtop, Three Applications

Every application shares the same carryable, closed-beam, interlocked body with twin Li-ion batteries and 6+ hours of runtime. The tube, detector and app change with the work.

GeoChem

80 kV for heavy and light rare earths

The industry's only field-portable XRF running to 80 kV, for heavy REEs, light REEs and the pathfinders Ag, Cd, Sn, Sb and Ba, plus 25 more elements used in mining and exploration. Three beams — 10, 40 and 80 kV — and five primary filters deliver 5–25 ppm detection limits across the REE suite, in minutes rather than weeks. GPS tags every result, and two cameras cover the chamber and the sample.

  • PX50 GeoChem is the affordable alternative: a 50 kV, 200 µA tube and 25 mm² detector, giving the best achievable limits on the light REEs while still reaching from magnesium through uranium. Choose it when the work doesn't need the heavy rare earths.
GeoChem
  1. 1Excitation source — 80 kV, three beams at 10 / 40 / 80 kV
  2. 2Detector — 50 mm² SDD, < 150 eV, 150k cps
  3. 3Detection limits — 5 – 25 ppm across the REE suite
  4. 4Beam filters — Five primary filters
The Breakthrough

A Benchtop XRF You Can Carry

First-Ever 80 kV Portable

An 80 kV miniature X-ray tube efficiently excites the K-shell lines of both light and heavy REEs — reaching detection limits no other portable XRF can.

Measures Heavy REEs

Tb, Dy, Ho, Er, Yb and more — high-energy K-lines avoid the spectral overlaps with Fe, Cu, and Ni that defeat conventional handhelds.

Battery-Powered & Shielded

Fully shielded and safety-interlocked, running 6+ hours on twin Li-ion batteries or AC power — carried from site to site with no loss of analytical power.

Two Cameras

One views the testing chamber; the second captures external photo-documentation, tagging results with high-resolution spatial coordinates.

Cloud-Enabled

Fully Cloud-enabled with built-in Wi-Fi, Bluetooth, and GPS for real-time results and reporting.

Familiar SciAps UI

Runs the same intuitive SciAps interface as the handhelds — data is easy to acquire, record, and share.

Elements

Element Coverage by Application

Every element the PowerHouse X is calibrated for, across all three applications — set it against any handheld X-Series model to see what the 80 kV benchtop adds. Each application carries its own calibrated package, listed below; others can be substituted on request, and cost depends on the element.

PowerHouse X covers 59 elements

Compare with
PowerHouse X only X-555 only Both (45)

Only the PowerHouse X measures (14)Ru, Rh, Pd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Re, Ir, Pt

Only the X-555 measures (1)Tl

By application

Point at one to see it on the table.

50 elements in GeoChem

Every element calibrated across each analyzer's standard applications. Other elements can be added on request for any model.

By the Numbers

PowerHouse X Specifications

Excitation source
80 kV miniature X-ray tube
Heavy REEs
Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu
Light REEs
La, Ce, Pr, Nd, Sm, Eu
Pathfinders
Ag, Cd, Sn, Sb, Ba
Element coverage
REEs + pathfinders + 25 more mining elements
Cameras
Two — testing-chamber view and external photo-documentation
Power
Twin Li-ion batteries (6+ hours) or AC power
Connectivity
Wi-Fi, Bluetooth, GPS; fully Cloud-enabled
Safety
Fully shielded and safety-interlocked
In Its Element

Where the PowerHouse X goes to work

FAQ

Frequently Asked Questions

Why does measuring heavy rare earths need 80 kV?

Heavy REEs such as Tb, Dy, Ho, Er and Yb are best measured on their K-shell lines, which need far more energy to excite than a 50 kV tube provides. Read on their L-lines instead, they overlap badly with common metals like Fe, Cu and Ni. The 80 kV tube reaches those K-lines, so the overlaps disappear.

Is the PowerHouse X really portable?

It runs 6+ hours on twin Li-ion batteries or on AC power, which also recharges them, and it is built as a closed-beam interlocked system for field use. It is a benchtop analyzer you can take to the site rather than a lab instrument that must stay put.

What detection limits can I expect on rare earths?

Between 5 and 25 ppm across the full suite of heavy and light REEs, depending on the element, in a few minutes per sample.

Which application should I choose?

GeoChem for rare earths and pathfinders at 80 kV, or the PX50 at 50 kV for soils, rock and ores from Mg to U; Alloy for grade ID and light elements in metal; Precious Metals for gold, precious-metal alloys and jewelry.

Does it record where a sample was taken?

Yes. GPS is built in and results are tagged with spatial coordinates, and two cameras — one on the testing chamber, one external — document the sample itself.

Ready to find the right analyzer?

Talk with a SciAps expert to compare products, request a quote, or find the best solution for your application.

Contact Sales

Stay ahead of the curve

Get the latest application notes, product updates, industry insights, and analytical innovations delivered to your inbox.